How to Read a Lab Report

What purity, identity, endotoxin and sterility results can and cannot tell you, and how to spot a weak report.

Educational guide · For laboratory research use only

Overview

A lab report can show a large purity number, a graph and a page of technical terms. But what does it actually prove? The useful answer starts with knowing which question each test was designed to answer.

The most common lab report for a research material is a certificate of analysis (COA): a document that reports test results for a specific batch of material. This guide explains how to read one. It uses general examples only.

What you will learn: the parts of a COA, what HPLC purity and mass spectrometry each show, what other tests mean, why independent testing matters, and which red flags to watch for.

The parts of a typical report

  • Product identity: the name of the material the report describes.
  • Lot or batch number: the identifier that links the report to one production batch. Results apply to that batch, not to the product in general.
  • Test date: when the analysis was done.
  • Testing laboratory: who performed the tests, and whether that lab is independent of the seller.
  • Methods: how each result was obtained, such as HPLC or mass spectrometry.
  • Specification and result: the specification is the acceptance limit (for example, "at least 98%"); the result is what the test found. A result means little without its specification.
  • Signature or accreditation: who approved the report, and under which quality standard.

HPLC purity

HPLC (high-performance liquid chromatography) pushes a sample through a column that separates its components. A detector records each component as it comes out, producing peaks on a graph called a chromatogram.

The purity percentage is usually the area of the main peak divided by the total area of all peaks counted. A chromatogram with one tall main peak and a few small impurity peaks supports a high purity result for that method.

A specification such as "≥ 98%" means the batch passes if the main peak is at least 98% of the measured signal. That number is not the same as the share of the powder's total weight: water and counter-ions are not counted, and some impurities may not be detected or may overlap.

Mass spectrometry and identity

Mass spectrometry (MS) measures the mass of molecules. For a peptide, the lab compares the observed mass with the expected mass calculated from its sequence. A close match is strong evidence that the expected chain is present.

Identity and purity are separate questions. HPLC shows how much of the measured sample is the main component; MS shows what that component is. A sample can match the expected mass and still contain impurities, so the two tests work best together.

Other tests that sometimes appear

TestQuestion it answers
Endotoxin (LAL test)How much bacterial endotoxin is present. Endotoxins can remain even when no live bacteria do.
SterilityWhether viable microorganisms were detected in the tested sample under the test conditions.
Water content (Karl Fischer)How much water the powder holds, which affects stability and net content.
Residual solventsWhether solvents from synthesis or purification remain, and how much.
Heavy metalsWhether metals such as lead or arsenic are present above a limit.
Peptide contentHow much of the powder's weight is the peptide itself, rather than water and counter-ions.

Sterility and endotoxin results do not substitute for each other, and neither can be inferred from a purity percentage.

Third-party versus in-house testing

In-house testing is done by the seller or manufacturer. Third-party testing is done by an independent lab with no stake in the result, which adds a separate source of evidence.

Accreditation adds more. ISO/IEC 17025 is the international standard for testing and calibration labs. An accredited lab has been assessed for competence in specific tests, so check that the test on your report falls within the lab's accredited scope.

Red flags checklist

  • No test method listed.
  • No laboratory name.
  • No test date.
  • Results with no specification or units.
  • Identical numbers across reports for different lots.
  • Signs of editing, such as mismatched fonts or blurred areas.
  • A purity number with no chromatogram, or an identity claim with no mass data.
  • A report that cannot be matched to the lot number on the vial.

A missing result is unknown, not a pass.

Worked example: a high purity result can hide a different problem

The following numbers are fictional and illustrate how to read a report. They are not a real laboratory report and not a product specification.[5]

Reported itemExampleWhat it tells you
HPLC area purity99.2%The main peak accounts for 99.2% of the included detector signal.
Identity by mass spectrometryConsistent with referenceSupports identity within the limits of the method.
Labeled net content10 mgThe stated amount, not a measurement.
Measured net content7.8 mg78% of the stated amount, if the measurement uses the same basis.
Endotoxin resultNot testedNo conclusion about endotoxin from this report.

Even with 99.2% area purity, the measured amount is 22% below the label claim. The purity percentage does not correct that difference. Compare content with its own stated acceptance limit and confirm the basis of the measurement. Do not multiply the HPLC area percentage by the labeled amount to estimate net content.

Three report terms that are easy to confuse

  • Not detected: the method did not detect the target under its stated conditions; this does not prove absolute absence.
  • Not tested: no result was obtained for that test.
  • Pass: the reported result met the stated acceptance rule for that test. Check what the rule was.

Frequently asked questions

Can a sample be 99% pure and still contain less material than its label states?

Yes. HPLC area purity compares measured detector signals. Net content is an amount determined by a suitable quantitative test. One does not establish the other.

What if the mass spectrometry result does not match the expected identity?

A high purity result cannot resolve an identity mismatch. Record the discrepancy and seek clarification or qualified review. Do not regard the sample as having verified identity until the issue is resolved.

How can I tell whether a COA belongs to the exact lot I am reviewing?

Match the material name, lot identifier and lab sample or report number to the relevant records. If the lab uses a different identifier, there should be a documented link between the tested sample and the lot.

If sterility testing passes, does that mean endotoxins are absent?

No. Sterility testing looks for viable microorganisms under defined conditions. Endotoxin testing addresses bacterial components that may remain even when viable microorganisms are not detected.

What does a report saying “pass” or “not detected” actually prove?

A pass depends on the specified limit. Not detected depends on the method and its detection capability. Neither means all unreported tests passed; check the units, methods, limits and missing fields.

References

  1. Separation, detection and quantitation of peptides by liquid chromatography | J Chromatogr A, 2009
  2. Characterization of synthetic peptides by mass spectrometry | Methods Mol Biol, 2024
  3. Pyrogen and endotoxins testing: questions and answers | U.S. FDA guidance
  4. National Voluntary Laboratory Accreditation Program (NVLAP) | NIST
  5. Model certificate of analysis, TRS 1010 Annex 4 | World Health Organization, 2018